八分钟的温暖 发表于 2014-10-14 09:33:27

有关思科无线网桥AIR-BR1310G-E-K9故障解决

    先有两台思科无线网桥设备【型号:AIR-BR1310G-E-K9】起桥接作用,其中一台无线网桥作为root bridge,另外一台无线网桥作为non-root bridge,先两台无线网桥彼此之前不能正常通信,主要故障应该在非根的这一台无线网桥上。通过console方式连接到非根的无线网桥上查看日志,发现有以下报错信息:
*Mar1 00:04:01.251: %DOT11-4-UPLINK_ESTABLISHED: Interface Dot11Radio0, Associated To AP Kongya1 0017.94fe.2870
*Mar1 00:04:01.252: %LINK-3-UPDOWN: Interface Dot11Radio0, changed state to up
*Mar1 00:04:01.416: %DOT11-4-UPLINK_DOWN: Interface Dot11Radio0, parent lost: Received deauthenticate (2) not valid
*Mar1 00:04:01.418: %LINK-3-UPDOWN: Interface Dot11Radio0, changed state to down
   另外本人在查看根无线网桥时发现其Virtual-Dot11Radio0端口处于down状态,应该是由于Virtual-Dot11Radio0端口不正常导致两台无线网桥不能正常工作。
Kongya1#show ip int br
Interface                  IP-Address      OK? Method Status                Protocol
BVI1                     10.125.15.21    YES NVRAMup                  up      
Dot11Radio0                unassigned      YES TFTP   up                  up      
FastEthernet0            unassigned      YES NVRAMup                  up      
Virtual-Dot11Radio0      unassigned      YES TFTP   down                  down   
   以下是在根无线网桥收集的日志信息:
*Jul 13 22:10:07.267: %DOT11-6-ASSOC: Interface Dot11Radio0, Station Kongya2 0018.18f4.e230 Reassociated KEY_MGMT
*Jul 13 22:10:07.307: %DOT11-6-DISASSOC: Interface Dot11Radio0, Deauthenticating Station 0018.18f4.e230 Reason: Sending station has left the BSS

请大神们帮忙看一看,此故障如何解决,谢谢!

调皮的小五郎 发表于 2014-10-14 10:35:32


http://www.zxmh.net/html/book10/


看帖顶帖这是必须滴!

雅蜜雅蜜 发表于 2014-10-14 21:54:47

拿分走人

klinuxe 发表于 2014-11-26 14:52:55

桥接没做好拿分走人呵呵,楼下继续!

jimsun 发表于 2015-10-17 06:38:44

谢谢分享!顶起!

jimsun 发表于 2015-10-17 06:40:34

谢谢分享!顶起!
页: [1]
查看完整版本: 有关思科无线网桥AIR-BR1310G-E-K9故障解决