ITAA实验室 发表于 2012-6-9 10:40:13

【Juniper技术分享】如何在各种平台上面检查DOM/DDM

转载请注明:WWW.XUEXIZU.COM

Optical modules data
Optical modulesWavelengthTx power (dBm)Rx power (dBm)Typical power budgetType reach


MinMaxMinMax


Gigabit Ethernet
GE SX850-9.5-3-1707.5~250m (OM1 - MM 62.5μm)~500m (OM2 - MM 50μm)
GE LX/LH1310-9.5-3-20-38.510km (SMF μm)
GE ZX155005.2-24-32480km (SMF 10 μm)
10 Gigabit Ethernet
10GE LR1310-8.20.5-140.5
10km (SMF 10μm)
10GE ER1550-4.74-15.8-1
40km (SMF 10μm)
10GE ZR155004-24-7
80km (SMF 10μm)
Packet Over SONET / SDH (POS) OC-3 / STM-1
OC-3 / STM-1 Multimode SR850-20-14-23-872km (MMF)
OC-3 / STM-1 SR1310-15-8-23-8
2km (SMF 10μm)
OC-3 / STM-1 IR-11310-15-8-28-8
15km (SMF 10μm)
OC-3 / STM-1 LR-11310-50-34-10
40km (SMF 10μm)
OC-3 / STM-1 LR-21550-50-34-10
80km (SMF 10μm)
Packet Over SONET / SDH (POS) OC-12 / STM-4
OC-12 / STM-4 SR-11310-15-8-23-8
2km (SMF 10μm)
OC-12 / STM-4 IR-11310-15-8-28-8
15km (SMF 10μm)
OC-12 / STM-4 LR-11310-32-28-8
40km (SMF 10μm)
OC-12 / STM-4 LR-21550-32-28-8
80km (SMF 10μm)
Packet Over SONET / SDH (POS) OC-192 / STM-64
OC-192 / STM-64 SR-1
-80-110
2km (SMF 10μm)
OC-192 / STM-64 IR-21550-44-15-11540km (SMF 10μm)
OC-192 / STM-64 LR-2155004-24-72680km (SMF 10μm)

以下演示如何在各种平台上面检查DOM/DDM7600 ——ALL line card7600#sh inte tenGigabitEthernet 1/1 transceiverTransceiver monitoring is disabled for all interfaces.ITU Channel not available (Wavelength not available),Transceiver is internally calibrated.If device is externally calibrated, only calibrated values are printed.++ : high alarm, +: high warning, -: low warning, -- : low alarm.NA or N/A: not applicable, Tx: transmit, Rx: receive.mA: milliamperes, dBm: decibels (milliwatts).                                           Optical   Optical         TemperatureVoltageCurrent   Tx PowerRx PowerPort       (Celsius)    (Volts)(mA)      (dBm)   (dBm)---------------------------------------------------Te1/1      27.5       0.00      50.1      -2.0      -7.87600#
Cisco 12000——Engine5 SIP-600show hw-module subslot X/Y transceiver Z (idprom|status)GSR#show hw-module subslot 10/0 transceiver 0 idpromIDPROM for transceiver POS10/0/0:Description                               = XFP optics (type 6)Transceiver Type:                         = OC192 + 10GBASE-L (65)Product Indentifier (PID)               = QFCT-7081Vendor Revision                           = B2Serial Number (SN)                        = XXXXXXXXXVendor Name                               = CISCO-AGILENTVendor OUI (IEEE company ID)            = 00.30.D3 (12499)CLEI code                                 = WMOTBEVAABCisco part number                         = 10-1989-02Device State                              = Enabled.Date code (yy/mm/dd)                      = 06/06/30Connector type                            = LC.Encoding                                  = 64B/66B                                              SONET Scrambled                                              NRZMinimum bit rate                        = 9900 Mbits/sMaximum bit rate                        = 10500 Mbits/sGSR#sh hw-module subslot 10/0 transceiver 0 statusThe Transceiver in slot 10 subslot 0 port 0 is enabled.Module temperature                        = 18.148 CTransceiver Tx bias current               = 29416 uAmpsTransceiver Tx power                      = -1 dBmTransceiver Rx optical power            = 0 dBmGSR#
Cisco CRS(-1 / -3)——4x10GE 8x10GEshow controllers TenGigE X/Y/Z/K phy | utility head -n 22RP/0/RP1/CPU0:CRS#show controllers tenGigE 0/0/0/0 phy | utility head -n 22XENPAK Information:===================Vendor Name: CiscoVendor PN: B1G-F4T-X3NP4KVendor Rev: 1Vendor SN: x9j29csi3kdPackage OUI: 00c09820Vendor OUI: 00000000Vendor Date Code: 2009010101
Center Wavelength:chan0 = 1310.00 nmchan1 =   0.00 nmchan2 =   0.00 nmchan3 =   0.00 nm
Digital Optical Monitoring:Transceiver Temp: 36.406 CLaser Bias Current: 263.5200 mALaser Output Power: 0.7432 mW, -1.3 dBmReceive Optical Power: 0.3272 mW, -4.9 dBmRP/0/RP1/CPU0:CRS#
Cisco CRS(-1 / -3)——POSshow controllers SONET X/Y/Z/K | be OptRP/0/RP0/CPU0:CRS#show controllers SONET X/Y/Z/K | be OptThu Dec2 14:48:27.683 CETOptics type: OC192 + 10GBASE-LClock source: internal (actual) internal (configured)Rx S1: 0x0Tx S1: 0xfOptical Power Monitoring (accuracy: +/- 1dB)Rx power = 0.2621 mW, -5.8 dBmTx power = 0.4207 mW, -3.8 dBmTx laser current bias = 49.3 mA
RP/0/RP0/CPU0:CRS#
Cisco CRS(-1 / -3)——SIP / SPAshow hw-module subslot X/Y/Z status pluggable-optics KRP/0/RP0/CPU0:CRS#show hw-module subslot 0/7/1 status pluggable-optics 0Mon Nov 21 10:40:26.209 CETSPA 0/7/1 device pluggable-optics 0/0 info:int Sonet 7/1/0:      State: Enabled      Environmental Information - raw values                Temperature: 36.18 C                Supply voltage: 32998 in units of 100uVolt                Tx bias: 9624 in units of 2uAmp                Tx power: -5 dBm (2491 in units of 0.1 uW)                Rx power: -4 dBm (3014 in units of 0.1 uW)      Transceiver: Enabled      SW TX Fault: unavailable      SW LOS: unavailable      No active alarms      No active warnings      Version Identifier (VID): V01      Product Identifier (PID): SFP-OC48-SR      Part Number (PN): 10-1961-01      CLEI: WM1T2TTAAARP/0/RP0/CPU0:CRS#
Cisco CRS(-1 / -3)——4x10GE IPoDWDMshow controllers dwdm X/Y/Z/KRP/0/RP0/CPU0:CRS#show controllers dwdm 0/0/0/0 opticsOptics Status         Optics Type:Cisco 10Gb DWDM         Wavelength Info: C-Band, MSA ITU Channel=37, Frequency=194.30THz, Wavelength=1542.936nm         TX Power = 4.82 dBm         RX Power = -14.99 dBmRP/0/RP0/CPU0:CRS#
Juniper JUNOS devices——All linecardsshow interfaces diagnostics optics X/Yuser@host> show interfaces diagnostics optics so-7/0/0Physical interface: so-7/0/0Link : 0Laser bias current                        :50.776 mALaser output power                        :0.4030 mW / -3.95 dBmLaser temperature                         :29.0 degrees C / 84.2 degrees FLaser rx power                            :0.4671 mW / -3.31 dBmLaser bias current high alarm             :OffLaser bias current low alarm            :OffLaser bias current high warning         :OffLaser bias current low warning            :OffLaser output power high alarm             :OffLaser output power low alarm            :OffLaser output power high warning         :OffLaser output power low warning            :OffLaser temperature high alarm            :OffLaser temperature low alarm               :OffLaser temperature high warning            :OffLaser temperature low warning             :OffLaser rx power high alarm               :OffLaser rx power low alarm                  :OffLaser rx power high warning               :OffLaser rx power low warning                :OffModule not ready alarm                  :OffModule power down alarm                   :OffTx data not ready alarm                   :OffTx not ready alarm                        :OffTx laser fault alarm                      :OffTx CDR loss of lock alarm               :OffRx not ready alarm                        :OffRx loss of signal alarm                   :OffRx CDR loss of lock alarm               :OffLaser bias current high alarm threshold   :130.000 mALaser bias current low alarm threshold    :10.000 mALaser bias current high warning threshold :120.000 mALaser bias current low warning threshold:12.000 mALaser output power high alarm threshold   :0.8910 mW / -0.50 dBmLaser output power low alarm threshold    :0.2230 mW / -6.52 dBmLaser output power high warning threshold :0.7940 mW / -1.00 dBmLaser output power low warning threshold:0.2510 mW / -6.00 dBmLaser temperature high alarm threshold    :90.0 degrees C / 194.0 degrees FLaser temperature low alarm threshold   :-5.0 degrees C / 23.0 degrees FLaser temperature high warning threshold:85.0 degrees C / 185.0 degrees FLaser temperature low warning threshold   :0.0 degrees C / 32.0 degrees FLaser rx power high alarm threshold       :1.2589 mW / 1.00 dBmLaser rx power low alarm threshold      :0.0323 mW / -14.91 dBmLaser rx power high warning threshold   :1.1220 mW / 0.50 dBmLaser rx power low warning threshold      :0.0363 mW / -14.40 dBm

http://www.juniper.net/techpubs/en_US/junos9.5/information-products/topic-collections/swcmdref-interfaces/show-interfaces-diagnostics-optics-sonet.html

haonameless2 发表于 2012-6-9 12:54:37

{:6_268:}

haonameless2 发表于 2012-6-9 12:54:50

{:6_267:}

danny 发表于 2012-6-9 14:37:02

{:6_267:}
页: [1]